Open call for tenders

Medical devices and medical consumables for interventional cardiology – stents and distal embolic protection.

Medical equipments, pharmaceuticals and personal care products · for PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES · North Macedonia

What the buyer wants

Medical devices and medical consumables for interventional cardiology – stents and distal embolic protection.

26 lots

  1. Medical devices and medical consumables for interventional cardiology – stents and distal embolic protection.
  2. Coronary stent with a sinusoidal configuration and a permanent polymer coating containing a cytostatic agent from the “-limus” family (DES), with a platinum-iridium core for enhanced radiopacity, an outer cobalt-chromium layer, and platinum-iridium markers; minimum stent diameter range 2.25–4.0 mm …
  3. Coronary stent with a permanent polymer coating containing a cytostatic agent from the LIMUS family (DES), with a platinum-iridium core for enhanced radiopacity, an outer cobalt-chromium layer, and platinum-iridium markers; minimum stent diameter range 2.0–5.00 mm, with overexpansion capability up …
  4. Coronary stent designed for the treatment of large-lumen blood vessels, with high radial and axial strength, made of platinum-chromium alloy, abluminally coated with a bioresorbable PLGA polymer and the cytostatic agent everolimus (DES), with a dual-layer balloon system, a diameter range of 3.5–5 m…
  5. Coronary stent made of platinum-chromium alloy, with a thin stent strut profile ≤81 μm, a non-linear link design with an open-cell configuration, abluminally coated with a bioresorbable PLGA polymer and the cytostatic agent everolimus (DES), with a dual-layer balloon system, a diameter range of 2.2…
  6. Self-expanding cobalt-chromium stent for carotid arteries, compatible with a 0.014" guidewire and a 5F introducer sheath, with a straight and tapered closed-cell design, a diameter range of 6–10 mm, and a length range of 30–50 mm.
  7. Coronary stent made of cobalt-chromium alloy, with an open-cell design and a biodegradable polymer coating, coated with the immunosuppressive drug sirolimus, with a stent strut thickness of 60 µm, featuring PROBIO coating (amorphous silicon carbide), a diameter range of 2.25–4 mm, and a length rang…
  8. Peripheral balloon-expandable stent, made of cobalt-chromium, with an OTW (over-the-wire) system, compatible with a 6F introducer sheath, with a strut thickness of 110 µm (for stents with diameters of 5–7 mm), featuring PROBIO coating, with 2 markers, on a 90, 135, and 170 cm delivery catheter, wit…
  9. Coronary stent made of cobalt-chromium alloy, with a non-linear multi-link cell design, coated with a permanent polymer and the cytostatic agent everolimus (DES), with a diameter range of 2–4 mm and a length range of 8 mm to at least 38 mm, compatible with a 5F guiding catheter for all sizes.
  10. Coronary stent made of cobalt-chromium alloy, with a multi-link, non-linear link stent design, intended for large-diameter coronary arteries, coated with a permanent polymer and the cytostatic agent everolimus (DES), with a low stent crossing profile of ≤0.039" (for a 3 mm stent diameter), a diamet…
  11. Peripheral nitinol stent system, self-expanding, with a woven mesh design, flexible and kink-resistant, intended for interventions in the femoral and popliteal arteries, with a diameter range of 4.5–7.5 mm and a stent length range of 20–200 mm, compatible with a 6F introducer sheath.
  12. Self-expanding carotid stent system made of nitinol alloy, with a closed-cell design, an RX system, with a straight or tapered diameter ranging from 6.0 to 10.0 mm and lengths ranging from 20 to 40 mm, compatible with a 6F guiding introducer sheath.
  13. Distal embolic protection system for carotid artery stenting, featuring technology for independent deployment of a 0.014" guidewire, three levels of wire support, and subsequent deployment of an embolic protection filter with diameters of 5 and 7.2 mm and pore size of at least 120 µm; the system in…
  14. Coronary CoCr DES stent designed for long, complex, and bifurcation lesions, coated with a bioresorbable polymer containing a cytostatic agent from the “LIMUS” family, selectively applied to the abluminal surface at 3.9 μg/mm, with an open-cell design, a diameter range of 2.0–4.5 mm, and a length r…
  15. Self-expanding carotid stent made of nitinol alloy, with a flexible, dual-layer micromesh closed-cell design for protection against embolization, with repositioning capability during deployment up to 50%, compatible with a 5F introducer sheath and an RX system, with a stent diameter range of 5–10 m…
  16. Peripheral stent-graft system, balloon-expandable, indicated for interventions in the renal and/or iliac arteries, consisting of a stainless-steel stent with an open-cell design, fully encapsulated in a single PTFE layer with a controlled pore size of 55 µm, with a diameter range of 5–10 mm and a l…
  17. Coronary stent-graft system, balloon-expandable, made of cobalt-chromium alloy, intended for the management of complications during interventions, with a maximum profile of 1.25 mm, compatible with a 5F catheter for diameters of 2.5–4.0 mm and a 6F catheter for diameters of 4.5 and 5.0 mm, with len…
  18. Peripheral stent-graft system with high radial strength, indicated for implantation in the iliac and renal arteries for the treatment of aneurysms, acute perforations, acute ruptures, and fistulas. Made of a cobalt-chromium (CoCr) stent covered with a 203 μm ePTFE layer. Balloon-expandable, with a …
  19. Balloon-expandable covered peripheral stent with a dual ePTFE layer, inner and outer. Made of CoCr alloy, with an open-cell design, featuring three radiopaque markers at each end of the stent and two markers on the balloon. Diameter range: 5–10 mm; length range: 17–57 mm; compatible with a 0.035" g…
  20. Self-expanding carotid stent made of nitinol, featuring technology designed to prevent plaque prolapse through the stent for permanent embolic protection, with a dual-layer design and an open-cell configuration, with a diameter range of 6–10 mm and a length range of 20–60 mm (for selected diameters…
  21. Coronary bioadaptor – coronary scaffold composed of three CoCr sinusoidal arrays, coated with a drug and a bioresorbable polymer, designed to unlock the scaffold six months after implantation; diameter range: 2.25–4.0 mm; length range: 14–38 mm.
  22. Coronary stent system (DES) with everolimus, featuring an ultrathin 50 µm cobalt-chromium L605 platform, coated with a biodegradable and biocompatible polymer that delivers everolimus (LIMUS family) for controlled drug release, with a hybrid cell design, equipped with platinum-iridium radiopaque ma…
  23. Dedicated bifurcation stent system for side branches, with sirolimus (DES) on a 65 µm cobalt-chromium L605 platform, featuring a biodegradable polymer coating (PLGA + PLLA) for controlled drug release (~30 days), with a main-branch anchoring segment with markers for positioning at the carina and os…
  24. Tapered stent system for the treatment of long, diffuse lesions using a single stent. Stent material: cobalt-chromium L605 alloy or equivalent; stent strut thickness: 65 µm; drug (active substance): sirolimus; polymer: biodegradable and biocompatible; delivery system: Rapid Exchange (RX) system; dr…
  25. Cobalt-chromium alloy coronary stent, multi-link, featuring a Peak-to-Valley stent design for the treatment of tapered (conically narrowed) coronary lesions with small and large diameters, coated with a permanent polymer and the cytostatic drug everolimus (DES), with a strut thickness of 81 µm, a d…
  26. Peripheral CoCr stent for BTK calcified arteries, coated with sirolimus at 1.4 μg/mm² and a fluoroacrylate trilayer coating, with drug release over 2 months (75% during the first month), open-cell design with alternating links, strut thickness of 75–85 µm, high radial strength, shortening of <3%, p…

Companies that won similar tenders

Companies that won public tenders in the same category (Medical equipments, pharmaceuticals and personal care products) since 2024, according to EU award notices. Likely competitors, or partners for a joint offer.

and 36 more.