Open call for tenders
Supplies for interventional cardiology
Medical consumables · for PHI Clinical Hospital Shtip · North Macedonia
What the buyer wants
Supplies for interventional cardiology
30 lots
- 1Manifold, 3-way, right-to-left flow, with a rotator, transparent, with three-sided handles, and pressure resistant up to 70 Bar
- 2 Manual angiographic contrast syringe, with or without a pressure gauge, with a minimum capacity of 10 cc or equivalent
- 3Tube extension (M/F), with a length range of 25 to 120 cm, suitable for high pressure from 75 to 1200 psi or equivalent
- 4 Hydrophilic set for transradial approach 10cm, 16cm, 25cm 5F-6F, RO throughout with hemostatic valve and ...
- 5 Hydrophilic Transfemoral Approach Set 10cm, 4F-9F RO full length with hemostatic valve and Side tube
- 6 Steel guidewire for establishing initial access and for catheters standard support stiffness, atraumatic flexible tip with ..
- 7 Hydrophilic Nitinol tapered tip guidewires coated with RO polyurethane with tungsten for visibility and a hydrophilic coating
- 8Hydrophilic Nitinol guidewires with tapered tip, coated with RO polyurethane with tungsten for visibility and a hydrophilic coating over the entire length, 0.020“ - 0.038”, 80cm - 300cm
- 9Guiding coronary catheters for transfemoral/transradial access, sizes 5-8F with various configurations including EBU (Extra Backup), ......
- 10Diagnostic angiographic catheters: coronary left, right, MP and pigtail, (mandatory diameters 4F, 5F, 6F), with double ..........
- 11Diagnostic angiographic catheter double braided SIM 2,3 Inner diameter 0.047" for 5F. Diameters from 4F to 6F, lengths from 100 to 125cm.
- 12 Vascular closure system with resorbable suture and collagen, in a set with introducer and guidewire of 70 cm in 6F and 8F or equivalent
- 13 PKI guidewire (0.014″), length range from min 190 cm to max 300 cm, with varying degrees of support for stenting and varying tip stiffness, hydrophilic or hydrophobic ...........
- 14 Hydrophilic guidewire Durasteel–stainless steel, hydrophilicity over a 20–30 cm length with a polymer coating, for high ...........
- 15 Coronary guidewire for chronic total occlusions 0.010“/0.014'' stainless steel, platinum taper tip, polymer-coated over the core, 30cm hydrophilic, tip 0.010”, for treatment of complex lesions,
- 16 CTO guidewire for chronic total occlusions, (0.014"), with a length range from 185 cm to 300 cm, elastic Nitinol body,.
- 17 CORONARY DILATATION BALLOON CATHETERS, SEMICOMPLIANT, Rx or OTW technique, hydrophilic coated with two balloon markers and .......
- 18 CORONARY DILATATION BALLOON CATHETERS, for focal and long lesions, LOW or SEMICOMPLIANT, Rx or OTW technique, with a sharpened tip with an entry profile of minimum (0.017"), RBP of minimum 18, OptiLEAP or equivalent
- 19 Balloon catheters for CORONARY dilation for focal and long lesions, Semi-compliant, with two markers, PEBAX or equivalent material,
- 20 NON COMPLIANT balloon catheters with low profile, for focal and long lesions, for in-stent and post-dilation dilation, with two markers, ".
- 21 Coronary Graft System stent for acute coronary perforations and ruptures, Monorail (Rapid exchange) design, coated with
- 22 Balloon-expandable recoated peripheral stent, with a dual ePTFE outer and inner layer. Made of a CoCr alloy, with open cells, with 3 radiopaque markers on the stent ends and 2 markers on the balloon
- 23 Coronary stent with a sinusoidal configuration and a permanent polymer coated with a cytostatic agent from the LIMUS family (DES), the stent has a core
- 24 Coronary stent for the left main artery with a sinusoidal configuration, with a permanent polymer coated with a cytostatic from the LIMUS family (DES
- 25 Coronary stent of Platinum Chromium (PtCr) alloy with ultra-thin struts ≤81 μm and an open-cell architecture for improved deliverability and conformability,
- 26 Coronary stent made of Cobalt-Chromium alloy, open-cell design with a biodegradable polymer coated with the immunosuppressive drug sirolimus,
- 27 Coronary DES COBALT CHROMIUM STENT for complex and bifurcation lesions coated with a bioresorbable polymer with a cytostatic agent from “LIMUS”
- 28 Coronary COBALT CHROMIUM STENT, with a permanent polymer, EVEROLIMUS DRUG, 100 micrograms per cm2, MULTI-LINK stent design, 3-3-3,
- 29 COBALT CHROMIUM ALLOY CORONARY STENT, multi-link non-linear link stent design for large diameter coronary arteries,
- 30.Coronary biodegradable vascular scaffold system made of a magnesium alloy, coated with an immunosuppressive drug of the limus family
Companies that won similar tenders
Companies that won public tenders in the same category (Medical consumables) since 2024, according to EU award notices. Likely competitors, or partners for a joint offer.
- PANEP · Slovakia161 wins · last 27 Oct 2026
- S. A. B. Medical · Slovakia69 wins · last 20 Oct 2026
- MAPO medical · Czechia29 wins · last 20 Oct 2026
- Myhrabc · Czechia21 wins · last 18 Aug 2026
- BATIST Medical · Czechia19 wins · last 30 Oct 2026
- MEDICA FILTER · Czechia17 wins · last 14 Jul 2026
- MGVIVA · Czechia15 wins · last 19 May 2026
- lekarna.cz · Czechia13 wins · last 28 Oct 2026
- medisap · Czechia12 wins · last 2 Jun 2026
- Uherskohradišťská nemocnice · Czechia11 wins · last 2 Nov 2026
- Newclip Technics · France8 wins · last 23 Sep 2026
- Labelians · France8 wins · last 21 Sep 2026
and 50 more.